Automatic Close Cup Flash Point (PMCC) Apparatus
Automatic Close Cup Flash Point (PMCC) Apparatus

Automatic Close Cup Flash Point (PMCC) Apparatus

Member Details

Changsha Friend Experimental Analysis Instrument Co., Ltd

Changsha,Hunan,China

Manufacturer,Scientific Researcher

  • Product Details
  • Company Profile

NEW Series of Petroleum product closed cup flash point tester, with excellent repeatability and reproducibility. It is available for oil refinery, and petroleum oil product company in LAB quality testing requirement. This closed cup flash point series apparatus is best choice for the final user.(like testing institution, oil lab, university, and fuel oil refinery etc.). If you had the experience of representing other brand (like Anton-paar, PAC, Koehler instrument, etc), we have the confidence to competie with them. (We have client who make the testing comparison sheet between our apparatus and PAC optiflash series and the testing result has almost no difference).

Automatic closed cup flash point tester FDT-0292

Scope of application

Automatic closed cup flash point tester is conformed to GB/T261, ASTM D93 and the latest ISO 2719:Determination of flash point -- pensky-martens closed cup method


Technical parameters

1. Working power: AC 220V ± 10%, 50Hz

2.Range: room temperature ~ 300 ℃;Resolution: 0.1℃

3.Heating speed:

5(℃ / min ) ~6(℃ / min )   ( ASTM D93 procedure A)

1(℃ / min )~1.5(℃ / min)( ASTM D93 procedure B )

4.Agitation speed:

90( r./min)~120(r./min).    (ASTM D93  procedure A)

250(r/min)±10(r/min).   (ASTM D93  procedure B)

5. Ignition: electronic ignition and the gas flame

6.Adapt to the environment temperature: 10-40 ℃

7.Adapt to the environment humidity: <85%

8.Total power consumption: 500W


Features:

1. Adopt FRIEND's special automatic ignition sensing system to automatically extinguish the fire when the fire occurs, to ensure the safety of the laboratory.

2, using a circular overall heating structure, heating more uniform, heating rate is more accurate

3, using air-cooled temperature control system to ensure that the furnace temperature is consistent

4, using automatic ignition, automatic opening, automatic detection, self-diagnosis function, one-button operation

5, with self-over temperature protection, over temperature range can be set freely

6, using touch screen display, real-time simulation tracking shows the function curve of heating and test time, real-time prompt function of operation interface